| MODEL | CL3000VB | |||||
| Power | 3kVA | |||||
| INPUT | ||||||
| Input voltage | 208/220/230/240VAC or 100/110/115/120/127VAC |
|||||
| Input frequency | 50Hz/60Hz (optional) | |||||
| Input voltage range | 110 ~ 295±5VAC (50% load); 140 ~ 295 ±5VAC (100% load) or 50/60/70/80 ~ 150±5VAC {60%/70%/80%/100% load) |
|||||
| Number of phases | 1 pha + N + PE | |||||
| Power factor | 0.98 | |||||
| Input current (full load) | 12.1A or 30A | |||||
| THD | <5% | |||||
| Bypass voltage range | 186VAC-252VAC | |||||
| OUTPUT | ||||||
| Voltage level | 208/220/230/240VAC or 100/110/115/120/127VAC can be set on the LCD |
|||||
| Power factor | 0.9 | |||||
| Voltage deviation | ±1% | |||||
| DC voltage component | ≤200mv | |||||
| Output crest factor | 3:01 | |||||
| FREQUENCY LEVEL | ||||||
| Mains mode | Same input power frequency | |||||
| Battery mode | 50/60±0.2Hz | |||||
| Phase-lock speed | ≤1Hz/s | |||||
| Waveform distortion | 100% linear load <3%; 100% non-linear load <5% | |||||
| SWITCHING TIME | ||||||
| Switching from mains mode to battery mode | 0 ms | |||||
| Switching from battery mode to mains mode | 0 ms | |||||
| Switching from mains mode to Bypass mode | <4ms | |||||
| Switching from Bypass mode to mains mode | <4ms | |||||
| Switching from mains mode to ECO mode | <10ms | |||||
| System efficiency | Full load | >90% | ||||
| ECO mode | >94% | |||||
| Inverter overload capacity | 105% -150% for 30s switches to Bypass mode and alarms; | |||||
| > 150% 300ms switches to Bypass mode and alerts; | ||||||
| ACQUY | ||||||
| Battery Type | Sealed dry lead-acid, maintenance-free | |||||
| DC voltage | 72V DC | |||||
| Acquy trong | 9AH/12V | |||||
| Number of batteries | 6 | |||||
| Charger | ||||||
| Output voltage | 82.5+0.9V | |||||
| CHARGING METHOD | 3 charging levels | |||||
| Input voltage range | 80VAC-300VAC or 40VAC-150VAC | |||||
| Charging current | Standard:1A; Long backup time: 6A(Optional 12A) | |||||
| Protection | Overheat protection, fan check protection | |||||
| Protection against L-N wrong wiring, output overload protection | ||||||
| Mute, cold start, AC auto-start | ||||||
| Control | RS232; SNMP card; USB (RS232 only by default) | |||||
| Communications | Functional software, status analysis, turning the UPS system on/off | |||||
| monitor UPS operating status, store history | ||||||
| Display | LCD/LED | |||||
| SYSTEM OPERATING ENVIRONMENT CONDITIONS | ||||||
| Operating environment | Operating temperature | 0 – 400C | ||||
| Storage temperature | 250C – 550C | |||||
| Humidity | 20 – 90% (non-condensing) | |||||
| Altitude | 0m- 1500m, above 1500m used with reduced performance | |||||
| Noise level | <50db | |||||
| UPS dimensions (W*D*H) mm | 191x452x341 (Long backup time) | |||||
| 191x452x341 (standard) | ||||||
| Dimensions including packaging (W*D*H) mm | (Long backup time) | 320x550x462 | ||||
| (Standard) | 320x550x462 | |||||
| Weight/Total weight (Kg) | (Long backup time) | 12.5/13.8 | ||||
| (Standard) | 24.0/25.3 | |||||
Key features of the DELTA 3kVA Online UPS:
• Online double-conversion technology
• Wide input voltage range
• Advanced technology improves power factor
• Pure sine wave with distortion <3%
• Self-diagnoses faults when the UPS starts up
• Advanced Battery Management (ABM] • Cold start function
• Automatically charges the battery when the UPS is off
• Lightning protection, earth leakage protection
• Short-circuit and overload protection
• Automatically adjusts fan speed according to load
• Battery expansion option
• RS232 communication port (SNMP Optional)
• Schedule UPS shutdown and restart via UPS management software