Riello UPS model SDU 6000




Ups riello model SDU 6000
Power:
Key features :
• UPS can be installed vertically (tower) or horizontally (rackmount), depending on customer preference.
The front of the digital display can be pulled out (using the provided keys) and rotated to suit the installation format.
• Low noise level (< 40dBA) thanks to PWM digital ventilation systems that control load- and temperature-dependent fan speed, using an inverter with a switching frequency (> 20kHz, above the audible range). Dual DIALOG is suitable for installation in any environment.
User option :
• Operating mode:
- On-line (VFI): runs continuously
- The UPS supports the load from the battery supply when the mains power fails or experiences sudden fluctuations.
- Smart UPS automatically operates in on-line mode (VFI) or line-interactive mode (VI); the mode depends on the stability of the power supply
- Emergency: The UPS only supports the load with its battery when there is no power - suitable for emergency lighting
- Conversion frequency of 50 or 60Hz
• Output voltage selection: 220-230-240 VAC single-phase or 380-400-415 VAC three-phase
• Automatic power restart via PowerShield³ software
• Ends battery discharge before the alarm.
POWER QUALITY
• Filtering, stable and reliable voltage - Online double-conversion (VFI) technology compliant with EN50091-3, with EMI filters
• Ensures typical output quality with IT load distortion at crest factors of 3:1
• Low impact on the power source, like a UPS with a sine wave input available today.
VERY RELIABLE
• Fully digital control
• No interruption via automatic bypass
• Bypasses can be activated manually
• Uses IMS (Insulated Metal Substrate) modules.
ADVANCED DIAGNOSTICS
• Status, measurements, and alarms available on the standard backlit display
• UPS can be digitally updated (upgradeable flash) .
• Reliable battery performance (automatic and manual battery testing)
• Extends battery life due to Low Ripple Current Discharge (LRCD)
• User-replaceable
•Backup time can be extended with additional battery packs
ENHANCE VOLTAGE
• Input protected by a resettable thermal-activated breaker
• Back protection: to prevent energy from being fed back into the power source when a fault occurs
• Increased short-circuit current on bypass
• Overload capacity: 150% on the inverter.
• Performance guaranteed at temperatures up to 40°C
• Instructions for switching to bypass
|
INPUT |
||
|
Rated voltage |
220 -230 -240 VAC |
|
|
Voltage threshold |
176 ~ 276 VAC |
|
|
Number of phases |
1 phase (2 wires + ground wire) |
|
|
Rated frequency |
50 Hz (45Hz ~ 65Hz) |
|
|
Power factor |
0.99 |
|
|
OUTPUT |
||
|
Power |
6KVA / 6KW |
|
|
Voltage |
220 VAC ± 1% |
|
|
Number of phases |
1 phase (2 wires + ground wire) |
|
|
Waveform |
True sine wave under all grid conditions, independent of the remaining capacity of the battery. |
|
|
Frequency |
Synchronized with the input source |
|
|
Efficiency |
88% (Grid mode, battery) |
|
|
Overload capacity |
>=105% within 10 minutes |
|
|
BYPASS MODE |
||
|
Bypass voltage range |
180÷264 Vac |
|
|
Bypass frequency |
± 5% |
|
|
Automatically switches to Bypass mode |
Overload, UPS fault, low battery level |
|
|
Maintenance switch |
Yes |
|
|
External bypass contact |
Yes |
|
|
BATTERY |
||
|
Battery Type |
12VDC sealed dry battery, service life > 5 years |
|
|
Backup time |
50% Load |
20 minutes |
|
100% Load |
8 minutes |
|
|
INTERFACE |
||
|
Control panel |
Start button / Alarm silence / Power off button |
|
|
LED displaying statuses |
Mains mode, battery mode, Bypass mode, load capacity, battery capacity, fault status alert. |
|
|
Communication port |
RS232/USB |
|
|
Management software |
Includes Winpower management software, allowing monitoring and automatic on/off of the UPS and system |
|
|
Switching time |
0 milliseconds |
|
|
OPERATING ENVIRONMENT |
||
|
Operating ambient temperature |
0 ~ 40 oC |
|
|
Operating environment humidity |
20~95%, non-condensing |
|
|
STANDARDS |
||
|
Noise level during operation |
45dB at a distance of 1m |
|
|
Electromagnetic field |
IEC 61000-4-2 (ESD) - Level 4 |
|
|
Conducted and radiated emissions |
IEC 62040-2 (>25A) |
|
|
Emergency Power Off (EPO) function |
Option |
|
|
DIMENSIONS / WEIGHT Catalogue |
||
|
UPS dimensions |
|
|
|
UPS and battery weight (kg) |
|
|
|
Battery dimensions |
|
|