SOJI 1-phase UPS elevator rescue kit for 3.7kW -22kW motors

Contact

Short Description

SOJI single-phase elevator rescue kit for 3.7kW -22kW motors uses advanced technology and has been proven by domestic and international companies.

SOJI 1-phase elevator rescue kit is intelligently designed and can be used with FUJI and YASKAWA elevator inverters, which has the task of supplying power to the elevator when the power goes out to bring the cabin to the nearest floor to open the door for passengers to exitThis automatic rescue unit (reserve source) will automatically charge the battery when power is available. When it goes crazy, the elevator rescue kit provides power to the elevator system thanks to the energy stored in the battery to bring the elevator to the nearest floor and open the door for passengers to get out.

 >

Outstanding features:
- Extremely simple connection with 1 input phase 220VAC/50Hz, 1 output phase 220VAC/50Hz and 1 rescue signal. 
- PWM inverter technology creates standard 2-phase sinusoidal voltage of 220VAC/50Hz
- Compatible with all inverters: Fuji Frenic Lift, Yaskawa L1000A, Emerson Unidrive SP,.... and all control systems
- Optimal protection mode for the device - The rescue elevator runs extremely smoothly thanks to VVVF

Features: 
- ARD/ERD rescue kit detects when mains power is lost
- ARD/ERD switches to single-phase voltage conversion mode 
- ARD/ERD switches the output voltage from mains mode to a reserve source converted from the battery (ATS function)
- The control system combines the VVVF inverter to return the elevator to the nearest floor, opening the door for guests to escape
- The control system outputs “stop ARD”. The ARD/ERD unit automatically turns off after receiving the “stop ARD” signal.
- The ARD/ERD unit automatically switches to mains power and charges the battery when power is restored.

Distribution and manufacturing unit:Lisa Control Technology Co., Ltd.
 
Model FJ615N: SOJI UPS power unit with capacity of 1.5KVA/1200W, 220V/50Hz
Model FJ620N: SOJI UPS capacity 2KVA/1600W, 220V/50Hz
Model FJ630N: SOJI UPS capacity 3KVA/2400W, 220V/50HZ

Model SJ-2K:    1-phase elevator rescue unit 2KVA/1600W, 220VAC/50HZ
Model SJ-3K:    1-phase elevator rescue unit  3KVA/2400W, 220VAC/50HZ
 
Contact us for direct consultation and receive the best prices for services and products. 
LISA CONTROL TECHNOLOGY COMPANY LIMITED
Tel/Fax: +84 24 7309 9997
Address (Office): No. 10 LK10 Ha Tri service land, Ha Cau Ward, Ha Dong District, City. Hanoi
Website:  www.lisatech.vn
  • Specifications
    1. Technical specifications of the SOJI 1-phase UPS elevator rescue device for motors 3.7kW-22kW:

      MODEL

      FJ605N

      FJ610N

      FJ615N

      FJ620N

      FJ630N

      Capacity

      500 VA / 300 W

      1000 VA / 800 W

      1500 VA / 1200 W

      2000 VA / 1600 W

      3000 VA / 2400 W

      DC INPUT

      Rated voltage

      12 V

      24 V

      36 V (S)

      48 V (H)

      48 V

      DC input range (default)

      10 ~ 15V

      20 ~ 30 V

      30 ~ 45 V (S)

      40 ~ 60 V (H)

      40 ~ 60V

      AC INPUT

      AC input range (bypass mode)

      0 ~ 121 V / 132 V / 138 V / 144 Vac for 100 V / 110 V / 115 V / 120 Vac ± 10 Vac

      0 ~ 242 V / 264 V / 276 V / 288 Vac for 200 V / 220 V / 230 V / 240 Vac ± 10 Vac

      AC input range (mains mode)

      100 V: 70 ~ 130 Vac    110 V: 80 ~ 140 Vac     115 V: 85 ~ 145 Vac

      120 V: 90 ~ 150 Vac    200 V: 145 ~ 260 Vac    220 V: 165 ~ 280 Vac

      230 V: 175 ~ 290 Vac   240 V: 185 ~ 300 Vac

      Frequency input range

      50 Hz / 60 Hz (auto-sense), 50 Hz / 60 Hz ± 5% ~ 15%

      Generator connection

      Available (generator input power is settable)

      OUTPUT

       

      Inverter output range

      100 V / 110 V / 115 V / 120 Vac ± 5% (settable)

      200 V / 220 V / 230 V / 240 Vac ± 5% (settable)

      AC output range (bypass mode)

      0 ~ 121 V / 132 V / 138 V / 144 Vac for 100 V / 110 V / 115 V / 120 Vac ± 10 Vac

      0 ~ 242 V / 264 V / 276 V / 288 Vac for 200 V / 220 V / 230 V / 240 Vac ± 10 Vac

      AC output range (mains mode)

      100 V: 90 ~ 110 Vac     110 V: 99 ~ 121 Vac     115 V: 103 ~ 126 Vac

      120 V: 108 ~ 132 Vac    200 V: 166 ~ 226 Vac    220 V: 188 ~ 245 Vac,

      230 V: 199 ~ 254 Vac    240 V: 210 ~ 264 Vac

      Output frequency

      50 / 60 Hz ± 0.3 Hz (settable)

      Waveform

      Pure sine wave

      Inverter efficiency

      Max. 75%

      Max. 80%

      Max. 85%

      Energy saving mode

      Settable (< 3% load) , enter in 80 s

      No-load shutdown

      Settable (< 3% load), shut down in 80 s

      Transfer time

      10 ms

      THDV

      (resistive load)

      ≤ 5%

      Protections

      Overload, short circuit (inverter), battery low voltage, battery overcharge, overtemperature

      Overload time

      (mains mode)

      120 s for 110%, 60 s for 125%, 10 s for 150% (transfer to bypass mode)

      Overload time

      (inverter mode)

      60 s for 110%, 10 s for 125%, 5 s for 150% (Shut down directly)

      Mute

      Automatic mute in 60 s or by manual

      BATTERIES

       

      Battery capacity

      (H: external expansion)

      12 V x 1

      12 V / 7 Ah x 2

      12 V / 9 Ah x 2

      12 V / 9 Ah x 3    (H: 12 V x 4)

      12 V / 9 Ah x 4

      Charging current

      Standard model (S): 1 A (default)

      Long time model (H): 10 A (default); < 10 A, set step 1 A; ≥ 10 A, set step 5 A

      Max. 10 A (H)

      Max. 15 A (H)

      ----

      Max. 20 A (H)

      Max. 25 A (H)

      Equalizing

      charge voltage

      Single battery 14.1 Vdc (default), 13.6 ~ 15 Vdc adjustable

      Floating charge voltage

      Single battery 13.5 Vdc (default), 13.2 ~ 14.6 Vdc adjustable

      Low voltage alarm point

      Single battery 10.8 Vdc (default), 9.6 ~ 13 Vdc adjustable

      Low voltage shutdown point

      Single battery 10.2 Vdc (default), 9.6 ~ 11.5 Vdc adjustable

      COMMUNICATIONS

       

      USB+RJ45

      Supports Windows® 98 / 2000 / 2003 / XP / Vista / 2008 / 7 / 8 / 10

      SNMP (optional)

      Power management from SNMP manager and web browser (standard with slot)

      OTHERS

       

      Operating temperature

      5℃ ~ 40℃

      Operating humidity

      Relative humidity ≤ 93%

      Noise level

      ≤ 50 dB (1m)

      Tower

      Dimensions (W×D×H) (mm)

      144 x 345 x 215 (S / H)

      144 x 410 x 215

      (S)

      144 x 345 x 215

      (H)

      190 x 467 x 335.5

      (S / H)

      Packaged dimensions (W×D×H) (mm)

      236 x 427 x 316 (S / H)

      236 x 492 x 316

      (S)

      236 x 427 x 316

      (H)

      320 x 592 x 462

      (S / H)

      Net weight (kg)

      7.0 (H)

      12.2 (S)

      11.6 (H)

      14.2 (S)

      18.5 (S)

      17.8 (H)

      28.1 (S)

      28.0 (H)

      Gross weight (kg)

      8.0 (H)

      13.2 (S)

      12.6 (H)

      15.2 (S)

      19.8 (S)

      18.8 (H)

      30.2 (S)

      30.0 (H)

      Rack mount

      Dimensions (W×D×H) (mm)

      --

      440 × 338 × 88

      (S)

      440 × 410 × 132 (S)

      Packaged dimensions (W×D×H) (mm)

      --

      611 × 448 × 208

      (S)

      611 × 505 × 235 (S)

      Net weight (kg)

      --

      14.6 (S)

      17.2 (S)

      21.3 (S)

      26.7 (S)

      Gross weight (kg)

      --

      16.8 (S)

      20.4 (S)

      24.5 (S)

      30.5 (S)

       
      Contact us for direct consultation and the best product and service pricing. 
      LISA CONTROL TECHNOLOGY CO., LTD 
      Tel/Fax: +84 24 7309 9997
      Address (Office): No. 10 LK10, Ha Tri Service Land Area, Ha Cau Ward, Ha Dong District, Hanoi City
      Website:  www.lisatech.vn

      Contact us for direct consultation and the best product and service pricing. 
      LISA CONTROL TECHNOLOGY CO., LTD 
      Tel/Fax: +84 24 7309 9997
      Address (Office): No. 10 LK10, Ha Tri Service Land Area, Ha Cau Ward, Ha Dong District, Hanoi City
      Website:  www.lisatech.vn