ARCODE TECHNICAL SPECIFICATIONS / TECHNICAL SPECIFICATIONS
FREQUENCY CONVERTER SYSTEM / DRIVER
|
Power Input (L1, L2, L3) |
AC 3 Ph., 320-420V, 50/60 Hz |
AC 3 Ph., 200-240V, 50/60 Hz |
|||||||||
|
Power Output (U, V, W) |
AC 3 Ph., 0-400V, 0-100Hz |
||||||||||
|
Model |
4B14A |
4B17A |
4B26A |
4C35A |
4C50A |
4D75A |
2B14A |
2B17A |
2B26A |
2C35A |
2C50A |
|
Nom. Output Current (Inom) |
14 A |
17 A |
26 A |
35 A |
50 A |
75 A |
14 A |
17 A |
126 A |
35 A |
50 A |
|
Max. Output Current (< 6 s) |
28 A |
34 A |
52 A |
70 A |
100 A |
150 A |
28 A |
28 A |
52 A |
70 A |
100 A |
|
Brake Resistor (B, P) |
50 Ω / 1 kW |
50 Ω / 1 kW |
40 Ω / 1 kW |
25 Ω / 2 kW |
18 Ω / 3 kW |
10 Ω / 6 kW |
50 Ω / 1 kW |
50 Ω / 1 kW |
40 Ω / 1 kW |
25 Ω / 2 kW |
18 Ω / 3 kW |
|
Inbuilt EMC Filters |
DC Reactor EMI/RFI Filter |
DC Reactor EMI/RFI Filter |
|||||||||
|
Evacuation (ES1, ES2) |
60-120VDC Battery Supply Input 220VAC Single Phase Line Supply Input |
60-120VDC Battery Supply Input 220VAC Single Phase Line Supply Input |
|||||||||
MICROPROCESSOR SYSTEM / CONTROLLER
|
Supply Voltage |
24VDC (20-28VDC) |
|
|
Encoder Options |
5V TTL, 10-30V HTL, EnDat, SSI, SinCos, BISS |
|
|
Serial Communication |
2 CANBUS (shaft and car) 3 RS485 (2 Full-Duplex, 1 Half Duplex) |
2 CANBUS (shaft and car) 3 RS485 (2 Full-Duplex, 1 Half Duplex) |
|
Relay Outputs |
4 Programmable Relay Output (10A@250VAC, 10A@30VDC) 1 Main contactor Relay Output (10A@250VAC, 10A@30VDC) |
4 Programmable Relay Output (10A@250VAC, 10A@30VDC) 1 Main contactor Relay Output (10A@250VAC, 10A@30VDC) |
|
Signal Inputs |
16 Programmable Input (24VDC, 3mA sink) Floor Level Magnetic Switches (ML1,ML2) |
16 Programmable Input (24VDC, 3mA sink) Floor Level Magnetic Switches (ML1,ML2) |
|
Transistors Outputs |
4 Programmable Transistor Output (open collector Imax:200mA) |
4 Programmable Transistor Output (open collector Imax:200mA) |
|
Door Bridging |
Door Bridging Board Connector (reserved) |
Door Bridging Board Connector (reserved) |
|
Cooling |
Air Ventilation and Aluminum Cooler |
Air Ventilation and Aluminum Cooler |
|
Safety circuit |
48-110-220VAC |
|
|
User Interface |
4 Digit Seven Segment plus 8 LED indicator |
4 Digit Seven Segment plus 8 LED indicator |
|
Logging |
SD Card |
SD Card |
Tel/Fax: +84 24 7309 9997
Address (Office): No. 10 LK10, Ha Tri Service Land Area, Ha Cau Ward, Ha Dong District, Hanoi City
Website: www.lisatech.vn

Features
- Connection:
CANbus communication cable connecting the control cabinet and the cabin top cabinet
Standard connection or via CANbus (up to 16 floors)
- Car position information is connected to the motor's encoder
- Ability to control 2 independent cabin doors
- Rescue system:
- Uses a single-phase 220VAC power source or battery to bring the elevator to the nearest floor or a designated floor
- Relative encoder (5V TTL or 10-30V HTL) or absolute encoder (Endat, SSI, SinCos or BISS)
- Automatically sets, stores parameters, and monitors information
- Leveling and early door opening feature
- High-precision floor leveling
- All control components can be further programmed
- Standby mode

Tel/Fax: +84 24 7309 9997
Address (Office): No. 10 LK10, Ha Tri Service Land Area, Ha Cau Ward, Ha Dong District, Hanoi City
Website: www.lisatech.vn