| MODELS | GPU30 | GPU45 | GPU60 | GPU90 | GPU120 | GPU200 |
| INPUT | ||||||
| Nominal voltage | 3Phase 200VAC/400VAC/480VAC | |||||
| Voltage tolerance | ± 15% | |||||
| Nominal frequency | 45Hz to 65Hz ±5% | |||||
| Input current harmonics | < 3% at full load (sinusoidal) | |||||
| OUTPUT | ||||||
| Nominal power (kVA) | 30 | 45 | 60 | 90 | 120 | 200 |
| Active power (kW) | 30 | 45 | 60 | 90 | 120 | 200 |
| Voltage | 200VAC 3 phase (other voltages available on request) | |||||
| Static regulation 0 -100% load | ±1% | |||||
| Dynamic regulation 100% | ±5%, recovering to 1% within 40 millisecond | |||||
| Frequency | 400Hz | |||||
| Frequency stability | ±0.01% Crystal controlled | |||||
| Overall Efficiency | 87% – 95% | |||||
| Max crest max | 3 : 1 | |||||
| RECTIFIER | ||||||
| AC Voltage Range | -25% +10% | |||||
| Efficiency | 93% - 97% | |||||
| Input Frequency Deviation | ± 5% | |||||
| Overload capacity | 120% continuous | |||||
| Current walk in | 5 seconds to maximum | |||||
| Overall current limits | 120% | |||||
| INVERTER | ||||||
| Total harmonic distortion | < 3% linear load | |||||
| Overload | 120% for 60s, 150% for 5s, 200% for 2s | |||||
| Waveform | Sinusoidal | |||||
| Load power factor | 0.7 - 1 | |||||
| Efficiency | 93% - 98% | |||||
| INFO FOR INSTALLATION | ||||||
| DIMENSION (WxDxH) mm | 700 x 750 x 1250 | 700x800x1575 | 1600x1000x2000 | |||
| Remote signal | Dry contact | |||||
| Ethernet connection | Standard with NetAgent | |||||
| CAN (with Remote Panel) | Optional | |||||
| Temperature range at sea level |
- 400C to + 550C (full load) 300C at 2000m (full load) |
|||||
| Relative humidity | < 90% | |||||
| Noise level | < 65dbA at 1meter | |||||
| IP rating | IP20 (IP42, IP54 optional) | |||||
| Altitude | Up to 2500m | |||||
| Standards | DFS400; ISO 6858; BS 2G 219; MIL-STD-704; SAE ARP 5015; EN62040-1-1; EN61558-2-6;En61000-6-4; EN61001-6-2 | |||||
- Sân bay dân dụng
- Sân bay quân sự
.jpg)